Lagerbeholdning:

Installation Temperature max. 60°C
Operating Temperature min. -40°C
Attenuation Coefficient b max. 0.0962
Epsilon r 2.29
Attenuation Coefficient b 0.0874
Attenuation Coefficient a 0.2203
Attenuation Coefficient a max. 0.2423
Calculated Power false
Centre Conductor Diameter 2.25mm
Centre Conductor Material Copper, Silver plated
Conductor Inner Diameter 0.75mm
Installation Temperature min. -20°C
Operating Temperature max. 105°C
Outer Conductor 2 Description Outer conductor
Outer Conductor 3 Description Outer conductor
Outer Conductor 4 Description Outer conductor
Screen Frequency max. 6GHz
Screen Frequency min. 0.1GHz
Outer Cond1 Coverage 93%
Outer Conductor1 Diameter 8mm
Outer Conductor1 Material Copper, Silver plated
Outer Cond2 Coverage 95%
Outer Conductor2 Diameter 8.6mm
Outer Conductor2 Material Copper, Silver plated
2002/96/EC (WEEE) no special marking needed
Class 1148
2006/1907/EC (REACH) compliant
2000/53/EC (ELV) compliant
Armoring 1 Description Armor
Armoring 2 Description Armor
Armoring 3 Description Armor
Armoring 4 Description Armor
Cable Category Flexible RF cable
Cable Family RADOX RF: Highly flame retardant LSFH alternatives to RG cables
Kabelgruppe - Kabel U43
Calc IL/Power up to Freq 17MHz
Capacitance 101.4pF/m
Centre Conductor Design Strand-07
CW Power 560W
CW Power Frequency 1GHz
Description RG214 LSFH, 50 Ohm, 6 GHz, 105°C, ø11.1 mm, RADOX® jacket, Flame retardant, Railway qualified
Dielectric Diameter 7.28mm
Dielectric Material PEX (Polyethylene cross-linked)
Distribution txt RG214 LSFH, 50 Ohm, 6 GHz, 105°C, ø11.1 mm, RADOX® jacket, Flame retardant, Railway qualified
Dynamic Bend Radius 170mm
Fire Test a EN 60332-1-2
Fire Test b IEC 60332-3-25
Halogen Free true
Halogen Test IEC 60754
ID RADOX_RF_214
Impedance 50Ohm
Impedance Tolerance ± 2Ohm
Insulation Resistance 10000000MOhm/m
Jacket Colour RAL 9005 - bk
Jacket Diameter 11.1mm
Jacket Material RADOX EM104
Jacket Tolerance 0.1mm
2011/65/EC (RoHS) compliant
Number of Cycles 50
Number of Screens 2
Only as Assembly false
Operating Frequency 6GHz
Operating Voltage 5kV
Outer Conductor1 Design Braid
Outer Conductor2 Design Braid
Print on Jacket HUBER+SUHNER RADOX_RF_214 50 Ohm (production order number)
Propagation Velocity 66% of c
Repeated Bend Radius 110mm
Weight 20.3kg/100m
Screen Effectiveness 81dB
Signal Delay 5.03ns/m
Smoke Test EN 61034-2
Static Bend Radius 50mm
Test Voltage 10kV