RADOX_RF_214
H+S | |
---|---|
Flame propagation standard | EN 60332-1-2IEC 60332-3-25 |
UV resistance | ISO 4892-2A |
Insulation resistance | 10000000 MΩ*m |
Operation temperature | -40 °C ... 105 °C |
Fire characteristics | free of halogenes, acc. standard IEC 60754 |
Velocity of signal propagation | 66 % |
Weight | approx. 203 g/m |
Signal delay | 5.03 ns/m |
Screening effectiveness | 81 dB at frequency 0.1 GHz ... 6GHz |
Product code | RADOX_RF_214 |
Operating Voltage (at sea level) | ≤ 5 kVrms |
Static bending radius | ≥ 50 mm |
Cable family | RADOX RF: Highly flame retardant LSFH alternatives to RG cables |
Available as assembly only | No |
Smoke test | EN 61034-2 |
Operating frequency | ≤ 6 GHz |
Repeated bending radius | 110 mm (bendings, up to 50) |
Cable group | U43 |
Capacitance | 101.4 pF/m |
Test voltage (50 Hz/1 min) | ≤ 10 kVrms |
Installation temperature | -20 °C ... 60 °C |
Impedance | 50 Ω +/-2Ω |
Dynamic bending radius | < 170 mm |