| H+S | 
                        | Side of bulkhead | protected side | 
                                    
                        | DC current | ≤ 2.5 A at 48 V , 2.5 A | 
                                    
                        | Moisture resistance according | MIL-STD-202, Method 106 | 
                                    
                        | Vibration according | MIL-STD-202, Method 204, Cond. D | 
                                    
                        | bre.att-ter-frequency-range-max | 2500 | 
                                    
                        | bre.att-ter-frequency-range-min | 0 | 
                                    
                        | Storage temperature | -40 °C ... 85 °C | 
                                    
                        | Residual pulse energy (typ.) | 250 µJ  (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) | 
                                    
                        | Thermal shock according | MIL-STD-202, Method 107, Cond. B | 
                                    
                        | DC supply voltage | 48 V | 
                                    
                        | Insertion loss typical | ≤ 0.2 dB | 
                                    
                        | Product code | 3402.26.0006-EX | 
                                    
                        | Main path connectors | Port 1: unprotected, TNC jack (female)Port 2: protected, TNC jack (female) | 
                                    
                        | Housing material / plating | Brass / SUCOPLATE (R) Plating | 
                                    
                        | Turn-off time | 20 sec. typically at 2.0 A and 25°C ambient temperature | 
                                    
                        | Ingress protection (IP Rating) | Mated  / IP65, according to IEC 60529 | 
                                    
                        | Capsule holder with chain | YES | 
                                    
                        | Mounting and grounding | MH25 (bulkhead mounting) | 
                                    
                        | Residual pulse voltage (typ.) | 550 V  (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) | 
                                    
                        | Return loss typical | ≥ 20 dB | 
                                    
                        | Surge current handling capability | 30 kA single, 20 kA multiple (test pulse 8/20 µs) | 
                                    
                        | Center contact, material / plating | Port 1: Copper Beryllium Alloy / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) | 
                                    
                        | Recovery time | 7 sec. at 25°C ambient temperature | 
                                    
                        | EMP can be install reversed | YES | 
                                    
                        | Mating cycles | 500 | 
                                    
                        | Weight | 119 g | 
                                    
                        | Exemptions | 6c | 
                                    
                        | Gas tube | Yes DC, GDT included, replaceable, 9071.99.0648 (SEMPER, 90 V) | 
                                    
                        | Directive | RoHS 2011/65/EU and (EU) 2015/863 | 
                                    
                        | Impedance | 50 Ω | 
                                    
                        | Operation temperature | -40 °C ... 85 °C | 
                                    
                        | Rating | Compliant with exemption | 
                                    
                        | Product description | GDT technology up to 2.5 GHz | 
                                    
                        | Frequency frame | 0 MHz to 2500 MHz | 
                                    
                        | CW power frame | 26 |