| H+S |
| Side of bulkhead |
protected side |
| DC current |
≤ 2.5 A at 48 V , 2.5 A |
| Moisture resistance according |
MIL-STD-202, Method 106 |
| Vibration according |
MIL-STD-202, Method 204, Cond. D |
| bre.att-ter-frequency-range-max |
2500 |
| bre.att-ter-frequency-range-min |
0 |
| Storage temperature |
-40 °C ... 85 °C |
| Residual pulse energy (typ.) |
250 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
| Thermal shock according |
MIL-STD-202, Method 107, Cond. B |
| DC supply voltage |
48 V |
| Insertion loss typical |
≤ 0.2 dB |
| Product code |
3402.26.0006-EX |
| Main path connectors |
Port 1: unprotected, TNC jack (female)Port 2: protected, TNC jack (female) |
| Housing material / plating |
Brass / SUCOPLATE (R) Plating |
| Turn-off time |
20 sec. typically at 2.0 A and 25°C ambient temperature |
| Ingress protection (IP Rating) |
Mated / IP65, according to IEC 60529 |
| Capsule holder with chain |
YES |
| Mounting and grounding |
MH25 (bulkhead mounting) |
| Residual pulse voltage (typ.) |
550 V (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
| Return loss typical |
≥ 20 dB |
| Surge current handling capability |
30 kA single, 20 kA multiple (test pulse 8/20 µs) |
| Center contact, material / plating |
Port 1: Copper Beryllium Alloy / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
| Recovery time |
7 sec. at 25°C ambient temperature |
| EMP can be install reversed |
YES |
| Mating cycles |
500 |
| Weight |
119 g |
| Exemptions |
6c |
| Gas tube |
Yes DC, GDT included, replaceable, 9071.99.0648 (SEMPER, 90 V) |
| Directive |
RoHS 2011/65/EU and (EU) 2015/863 |
| Impedance |
50 Ω |
| Operation temperature |
-40 °C ... 85 °C |
| Rating |
Compliant with exemption |
| Product description |
GDT technology up to 2.5 GHz |
| Frequency frame |
0 MHz to 2500 MHz |
| CW power frame |
26 |