S_06162_D-03
H+S | |
---|---|
Flame propagation standard | UL 1581 § 1080 (VW-1) |
Insulation resistance | 100000000 MΩ*m |
Operation temperature | -40 °C ... 85 °C |
Fire characteristics | free of halogenes |
Velocity of signal propagation | 82 % |
Weight | approx. 110 g/m |
Signal delay | 4.08 ns/m |
Screening effectiveness | 82 dB at frequency 0.001 GHz ... 6GHz |
Product code | S_06162_D-03 |
Operating Voltage (at sea level) | ≤ 0.75 kVrms |
Static bending radius | ≥ 40 mm |
Cable family | S: Low loss RF cables with foam PE dielectrics |
Available as assembly only | No |
Operating frequency | ≤ 6 GHz |
Repeated bending radius | 80 mm |
Cable group | S24 |
Capacitance | 82 pF/m |
Test voltage (50 Hz/1 min) | ≤ 1.5 kVrms |
Installation temperature | -20 °C ... 60 °C |
Impedance | 50 Ω +/-1.5Ω |