Installation Temperature max. |
60°C |
Operating Temperature min. |
-40°C |
Attenuation Coefficient b max. |
0.1431 |
Epsilon r |
2 |
Attenuation Coefficient b |
0.1301 |
Attenuation Coefficient a |
0.7648 |
Fire Test e |
CFR/JAR/CS Part 25 Appendix F |
Attenuation Coefficient a max. |
0.8412 |
Calculated Power |
false |
Centre Conductor Diameter |
0.54mm |
Centre Conductor Material |
Steel, Copper+Silver plated |
Conductor Inner Diameter |
0.18mm |
Installation Temperature min. |
-20°C |
Operating Temperature max. |
105°C |
Outer Conductor 2 Description |
Outer conductor |
Outer Conductor 3 Description |
Outer conductor |
Outer Conductor 4 Description |
Outer conductor |
Screen Frequency max. |
6GHz |
Screen Frequency min. |
1GHz |
Outer Cond1 Coverage |
96% |
Outer Conductor1 Diameter |
1.99mm |
Outer Conductor1 Material |
Copper, Silver plated |
Outer Cond2 Coverage |
90% |
Outer Conductor2 Diameter |
2.44mm |
Outer Conductor2 Material |
Copper, Silver plated |
2002/96/EC (WEEE) |
no special marking needed |
Class |
1148 |
2006/1907/EC (REACH) |
compliant |
2000/53/EC (ELV) |
compliant |
Armoring 1 Description |
Armor |
Armoring 2 Description |
Armor |
Armoring 3 Description |
Armor |
Armoring 4 Description |
Armor |
Cable Category |
Flexible RF cable |
Cable Family |
RADOX RF: Highly flame retardant LSFH alternatives to RG cables |
Kabelgruppe - Kabel |
U4 |
Calc IL/Power up to Freq |
17MHz |
Capacitance |
94.5pF/m |
Centre Conductor Design |
Strand-07 |
CW Power |
110W |
CW Power Frequency |
1GHz |
Description |
RG316D/RD316 LSFH, 50 Ohm, 8 GHz, 105°C, ø3.2 mm, RADOX® jacket, Flame retardant, Railway qualified |
Dielectric Diameter |
1.53mm |
Dielectric Material |
SPEX (Crosslink Foam PE) |
Distribution txt |
RG316D/RD316 LSFH, 50 Ohm, 8 GHz, 105°C, ø3.2 mm, RADOX® jacket, Flame retardant, Railway qualified |
Fire Test a |
EN 60332-1-2 |
Fire Test b |
EN 50305, 9.1.2 |
Fire Test c |
IEC 60332-3-24 |
Fire Test d |
UL 1581 § 1100 |
Halogen Free |
true |
Halogen Test |
IEC 60754 |
ID |
RADOX_RF_316_D |
Impedance |
50Ohm |
Impedance Tolerance ± |
2Ohm |
Inner Cond Res DC |
234Ohm/km |
Insulation Resistance |
10000000MOhm/m |
Jacket Colour |
RAL 9005 - bk |
Jacket Diameter |
3.2mm |
Jacket Material |
RADOX EM104 |
Jacket Tolerance |
0.1mm |
2011/65/EC (RoHS) |
compliant |
Number of Cycles |
50 |
Number of Screens |
2 |
Only as Assembly |
false |
Operating Frequency |
8GHz |
Operating Voltage |
1.5kV |
Outer Cond Resistance DC |
19Ohm/km |
Outer Conductor1 Design |
Braid |
Outer Conductor2 Design |
Braid |
Print on Jacket |
HUBER+SUHNER RADOX_RF_316_D 50 Ohm (production order number) |
Propagation Velocity |
70.1% of c |
Repeated Bend Radius |
30mm |
Weight |
2kg/100m |
Screen Effectiveness |
70dB |
Signal Delay |
4.72ns/m |
Smoke Test |
EN 61034-2 |
Specification Voltage |
300kV |
Static Bend Radius |
5mm |
Test Voltage |
3kV |
OBJECT_ID |
8674817 |