Radiation Test |
IEC 60068-2-5, proc. C |
Installation Temperature max. |
60 °C |
Operating Temperature min. |
-40 °C |
Attenuation Coefficient b max. |
0.0798 |
Attenuation Coefficient b |
0.0725 |
Attenuation Coefficient a |
0.8288 |
Attenuation Coefficient a max. |
0.9117 |
Calculated Power |
N |
Centre Conductor Diameter |
0.305 mm |
Centre Conductor Material |
Steel, Copper+Silver plated |
Conductor Inner Diameter |
0.102 mm |
Inner Cond Res DC |
747 Ohm/km, 802.2 Ohm/km |
Installation Temperature min. |
-20 °C |
Operating Temperature max. |
105 °C |
Outer Conductor 2 Description |
Outer conductor |
Outer Conductor 3 Description |
Outer conductor |
Outer Conductor 4 Description |
Outer conductor |
Screen Frequency max. |
1 GHz |
Screen Frequency min. |
0.01 GHz |
Outer Cond Resistance DC |
37 Ohm/km, 43 Ohm/km |
Outer Cond1 Coverage |
94 % |
Outer Conductor1 Diameter |
2 mm |
Outer Conductor1 Material |
Copper, Silver plated |
Phase vs Temperature Ratio |
8400 ppm |
2002/96/EC (WEEE) |
no special marking needed |
Class |
1148 |
2006/1907/EC (REACH) |
compliant |
2000/53/EC (ELV) |
compliant |
Ageing Test |
MIL-C-17 § 4.8.16 |
Alternative Cable |
RADOX_RF_179 |
Armoring 1 Description |
Armor |
Armoring 2 Description |
Armor |
Armoring 3 Description |
Armor |
Armoring 4 Description |
Armor |
Bending Force Moment |
0.02 Nm |
Bending Frequency |
1 GHz |
Bending Radius |
20 mm |
Bending Test Procedure |
360 |
Cable Category |
Flexible RF cable |
Cable Family |
Enviroflex: LSFH alternatives to RG cables |
CABLE GROUP Cable |
U5 |
Calc IL/Power up to Freq |
17 MHz |
Capacitance |
63 pF/m |
Centre Conductor Design |
Strand-07 |
Cold Bend Test |
MIL-C-17 § 4.8.19 |
CW Power |
45 W |
CW Power Frequency |
1 GHz |
Description |
RG179 LSFH, 75 Ohm, 3 GHz, 105°C, ø2.54 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Dielectric Diameter |
1.55 mm |
Dielectric Material |
SPEX (Crosslink Foam PE) |
Distribution txt |
RG179 LSFH, 75 Ohm, 3 GHz, 105°C, ø2.54 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Fire Test a |
UL 1581 § 1100 |
Fire Test b |
IEC 60332-2 |
Fire Test c |
EN 60332-1-2 |
Halogen Free |
1 |
Halogen Test |
IEC 60754 |
ID |
ENVIROFLEX_179 |
Impedance |
75 Ohm |
Impedance Tolerance ± |
3 Ohm |
Insulation Resistance |
10000000 MOhm/m |
Jacket Colour |
RAL 5015 - bl |
Jacket Diameter |
2.54 mm |
Jacket Material |
RADOX |
Jacket Tolerance |
0.07 mm |
2011/65/EC (RoHS) |
compliant |
Number of Cycles |
50 |
Number of Screens |
1 |
Only as Assembly |
N |
Operating Frequency |
3 GHz |
Operating Voltage |
1 kV |
Outer Conductor1 Design |
Braid |
Phase Temperature max. |
100 °C |
Phase Temperature min. |
-40 °C |
Phase vs. Bending |
0.7 °/GHz |
Print on Jacket |
HUBER+SUHNER ENVIROFLEX 179 75 Ohm (UL logo) AWM Style 3651 (production order number) |
Propagation Velocity |
70 % of c |
Repeated Bend Radius |
25 mm |
Weight |
1.11 kg/100m |
Screen Effectiveness |
40 dB |
Signal Delay |
4.78 ns/m |
Smoke Test |
EN 61034-2 |
Specification Voltage |
300 kV |
Static Bend Radius |
5 mm |
Temperature Rating UL |
105 °C |
Test Voltage |
2 kV |
UV Resistance Test |
IEC 60068-2-5, proc. C |
OBJECT_ID |
7516089 |