Installation Temperature max. |
60 °C |
Operating Temperature min. |
-40 °C |
Attenuation Coefficient b max. |
0.149 |
Attenuation Coefficient b |
0.142 |
Attenuation Coefficient a |
0.365 |
Attenuation Coefficient a max. |
0.383 |
Calculated Power |
N |
Centre Conductor Diameter |
0.95 mm |
Centre Conductor Material |
Copper, Silver plated |
Inner Cond Res DC |
23.655 Ohm/km, 24.9 Ohm/km |
Installation Temperature min. |
-20 °C |
Operating Temperature max. |
105 °C |
Outer Conductor 2 Description |
Outer conductor |
Outer Conductor 3 Description |
Outer conductor |
Outer Conductor 4 Description |
Outer conductor |
Screen Frequency max. |
5 GHz |
Outer Cond Resistance DC |
9.5 Ohm/km, 10 Ohm/km |
Outer Cond1 Coverage |
97 % |
Outer Conductor1 Diameter |
3.58 mm |
Outer Conductor1 Material |
Copper, Silver plated |
Outer Cond2 Coverage |
95 % |
Outer Conductor2 Diameter |
4.16 mm |
Outer Conductor2 Material |
Copper, Silver plated |
Phase vs Temperature Ratio |
9000 ppm |
2002/96/EC (WEEE) |
no special marking needed |
Class |
1148 |
2006/1907/EC (REACH) |
compliant |
Abrasion Test |
MIL-T-81490 - §4.7.19 - prod. II - modified |
2000/53/EC (ELV) |
compliant |
Ageing Test |
MIL-C-17 § 4.8.16 |
Alternative Cable |
RADOX_RF_142 |
Armoring 1 Description |
Armor |
Armoring 2 Description |
Armor |
Armoring 3 Description |
Armor |
Armoring 4 Description |
Armor |
Bending Force Moment |
0.35 Nm |
Cable Category |
Flexible RF cable |
Cable Family |
Enviroflex: LSFH alternatives to RG cables |
CABLE GROUP Cable |
U9 |
Calc IL/Power up to Freq |
17 MHz |
Capacitance |
94.5 pF/m |
Centre Conductor Design |
Wire |
Cold Bend Test |
MIL-C-17 § 4.8.19 |
CW Power |
225 W |
CW Power Frequency |
1 GHz |
Description |
RG142 LSFH, 50 Ohm, 6 GHz, 105°C, ø5 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Dielectric Diameter |
2.95 mm |
Dielectric Material |
SPEX (Crosslink Foam PE) |
Distribution txt |
RG142 LSFH, 50 Ohm, 6 GHz, 105°C, ø5 mm, RADOX® jacket, Flame retardant, UL AWM style 3651 |
Fire Test a |
EN 60332-1-2 |
Fire Test b |
UL 1581 § 1100 |
Fire Test c |
IEC 60332-2 |
Fire Test d |
EN 50305, 9.1.2 |
Halogen Free |
1 |
Halogen Test |
IEC 60754 |
ID |
ENVIROFLEX_142 |
Impedance |
50 Ohm |
Impedance Tolerance ± |
2 Ohm |
Insulation Resistance |
10000000 MOhm/m |
Jacket Colour |
black/bl line |
Jacket Diameter |
5 mm |
Jacket Material |
RADOX |
Jacket Tolerance |
0.1 mm |
2011/65/EC (RoHS) |
compliant |
Number of Cycles |
3000 |
Number of Screens |
2 |
Only as Assembly |
N |
Operating Frequency |
6 GHz |
Operating Voltage |
2.5 kV |
Outer Conductor1 Design |
Braid |
Outer Conductor2 Design |
Braid |
Phase Temperature max. |
100 °C |
Phase Temperature min. |
-40 °C |
Print on Jacket |
HUBER+SUHNER ENVIROFLEX 142 50 Ohm (UL logo) AWM Style 3651 (production order number) |
Propagation Velocity |
70.9 % of c |
Repeated Bend Radius |
50 mm |
Weight |
6 kg/100m |
Screen Effectiveness |
75 dB |
Signal Delay |
4.7 ns/m |
Smoke Test |
EN 61034-2 |
Specification Voltage |
300 kV |
Static Bend Radius |
30 mm |
Temperature Rating UL |
105 °C |
Test Voltage |
5 kV |
Thermal Stress Test |
IEC 61196-1 § 10.9 |
UV Resistance Test |
IEC 60068-2-5, proc. C |
OBJECT_ID |
7516085 |