3409.41.0092
H+S | |
---|---|
Side of bulkhead | protected side |
Gas tube | Yes DC, GDT included, replaceable, 9071.99.0548 (90 V) |
AISG insertion loss | 0.1 dB |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Vibration according | MIL-STD-202, Method 204, Cond. A |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 250 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Product description | High-power/low-IM GDT hybrid technology |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
DC supply voltage | 48 V |
Insertion loss typical | 0.1 dB |
Product code | 3409.41.0092 |
Main path connectors | Port 1: unprotected, 7/16 plug (male)Port 2: protected, 7/16 jack (female) |
Housing material / plating | Brass / SUCOPLATE (R) Plating |
Ingress protection (IP Rating) | IP67 |
AISG return loss | 18 dB |
Frequency frame | 690 MHz to 2690 MHz |
Mounting and grounding | MH110 (bulkhead mounting), M8 (screw), brk (bracket) |
Return loss typical | 26 dB |
Surge current handling capability | 30 kA single, 20 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Brass / Silver PlatingPort 2: Bronze / Silver Plating |
EMP can be install reversed | YES |
AISG frequency | 10 MHz |
PIM 3rd order | -160 dBc max. |
DC current | 13 A |
Mating cycles | 500 |
CW power frame | 1500 W |
Weight | 495 g |