3404.00.0012
H+S | |
---|---|
Ingress protection (comment) | Waterproof N interface, even in un-mated conditions: IP68 acc. IEC 60529 and MIL-STD 810G Method 512.5, Procedure I |
Side of bulkhead | unprotected side |
Gas tube | Yes DC, GDT included, not replaceable |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Vibration according | MIL-STD-202, Method 204, Cond. D |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 350 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Product description | Slim Line GDT technology |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
DC supply voltage | 28 V |
Insertion loss typical | ≤ 0.25 dB |
Product code | 3404.00.0012 |
Main path connectors | Port 1: unprotected, N jack (female)Port 2: protected, MMCX jack (female) |
Housing material / plating | Stainless Steel / Passivated (Plating) |
Ingress protection (IP Rating) | Unmated / IP68, according to IEC 60529 (30 min of water, 3 m) |
Static spark voltage | 150 V, +/- 20 % (@ 100 V/s) |
Frequency frame | 0 MHz to 3000 MHz |
Mounting and grounding | MH119 (bulkhead mounting) |
Return loss typical | ≥ 20 dB |
Surge current handling capability | 10 kA single, 5 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Copper Beryllium Alloy / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
DC current | 2 A |
Mating cycles | 500 |
CW power frame | ≤ 30 W |
Inline design | YES |
Weight | 67.7 g |