| H+S |
| Ingress protection (comment) |
Waterproof TNC interface, even in un-mated conditions : IP68 acc. IEC 60529 and MIL-STD 810G Method 512.5, Procedure I |
| Side of bulkhead |
protected side |
| Moisture resistance according |
MIL-STD-202, Method 106 |
| Vibration according |
MIL-STD-202, Method 204, Cond. D |
| bre.att-ter-frequency-range-max |
3000 |
| bre.att-ter-frequency-range-min |
0 |
| Storage temperature |
-40 °C ... 85 °C |
| Residual pulse energy (typ.) |
350 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
| Thermal shock according |
MIL-STD-202, Method 107, Cond. B |
| DC supply voltage |
28 V |
| Insertion loss typical |
≤ 0.25 dB |
| Product code |
3404.00.0011 |
| Main path connectors |
Port 1: unprotected, TNC jack (female)Port 2: protected, MMCX jack (female) |
| Housing material / plating |
Stainless steel / Passivated (Plating) |
| Ingress protection (IP Rating) |
Unmated / IP68, according to IEC 60529 (30 min of water, 3 m) |
| Static spark voltage |
150 V, +/- 20 % (@ 100 V/s) |
| Details |
CAS: 7439-92-1 Lead |
| Mounting and grounding |
MH119 (bulkhead mounting) |
| Return loss typical |
≥ 20 dB |
| Surge current handling capability |
10 kA single, 5 kA multiple (test pulse 8/20 µs) |
| Center contact, material / plating |
Port 1: Copper Beryllium Alloy / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
| DC current |
2 A |
| Mating cycles |
500 |
| Inline design |
YES |
| Weight |
36 g |
| Exemptions |
6c |
| Gas tube |
Yes DC, GDT included, not replaceable |
| Directive |
RoHS 2011/65/EU and (EU) 2015/863 |
| Impedance |
50 Ω |
| Operation temperature |
-40 °C ... 85 °C |
| Rating |
Compliant with exemption , Contains one or more SVHC >0,1% |
| Product description |
Slim Line GDT technology |
| Frequency frame |
0 MHz to 3000 MHz |
| Regulation |
REACH 1907/2006 Article 33 SVHC |
| CW power frame |
30 |