H+S |
Ingress protection (comment) |
Waterproof TNC interface, even in un-mated conditions : IP68 acc. IEC 60529 and MIL-STD 810G Method 512.5, Procedure I |
Side of bulkhead |
protected side |
Moisture resistance according |
MIL-STD-202, Method 106 |
Vibration according |
MIL-STD-202, Method 204, Cond. D |
bre.att-ter-frequency-range-max |
3000 |
bre.att-ter-frequency-range-min |
0 |
Storage temperature |
-40 °C ... 85 °C |
Residual pulse energy (typ.) |
350 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Thermal shock according |
MIL-STD-202, Method 107, Cond. B |
DC supply voltage |
28 V |
Insertion loss typical |
≤ 0.25 dB |
Product code |
3404.00.0011 |
Main path connectors |
Port 1: unprotected, TNC jack (female)Port 2: protected, MMCX jack (female) |
Housing material / plating |
Stainless steel / Passivated (Plating) |
Ingress protection (IP Rating) |
Unmated / IP68, according to IEC 60529 (30 min of water, 3 m) |
Static spark voltage |
150 V, +/- 20 % (@ 100 V/s) |
Details |
CAS: 7439-92-1 Lead |
Mounting and grounding |
MH119 (bulkhead mounting) |
Return loss typical |
≥ 20 dB |
Surge current handling capability |
10 kA single, 5 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating |
Port 1: Copper Beryllium Alloy / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
DC current |
2 A |
Mating cycles |
500 |
Inline design |
YES |
Weight |
36 g |
Exemptions |
6c |
Gas tube |
Yes DC, GDT included, not replaceable |
Directive |
RoHS 2011/65/EU and (EU) 2015/863 |
Impedance |
50 Ω |
Operation temperature |
-40 °C ... 85 °C |
Rating |
Compliant with exemption , Contains one or more SVHC >0,1% |
Product description |
Slim Line GDT technology |
Frequency frame |
0 MHz to 3000 MHz |
Regulation |
REACH 1907/2006 Article 33 SVHC |
CW power frame |
30 |