SUCOFEED 1/2 HF FR
| H+S | |
|---|---|
| Tensile strength | 700 N |
| Inductance | 0.2 µH/m |
| UV resistance | ISO 4892-2 |
| Insulation resistance | 5000 MΩ*km |
| Inner conductor resistance | 2.9 Ω/km |
| Fire characteristics | free of halogenes, acc. standard IEC 60754-2 |
| Velocity of signal propagation | 83 % |
| Weight | approx. 200 g/m |
| Outer conductor resistance | 3.9 Ω/km |
| Signal delay | 4 ns/m |
| Product code | SUCOFEED_1/2_HF_FR |
| CPR class | B2ca-s1a,d0,a1 |
| Operating Voltage (at sea level) | ≤ 1.27 kVrms |
| Available as assembly only | No |
| Smoke test | IEC 61034 |
| Cable group | M9 |
| Capacitance | 80.3 pF/m |
| Test voltage (50 Hz/1 min) | ≤ 2.5 kVrms |
| Installation temperature | -25 °C ... 60 °C |
| Flame propagation standard | IEC 60332-1IEC 60332-3EN 60332-1-2 |
| Operation temperature | -40 °C ... 85 °C |
| Screening effectiveness | 120dB |
| Static bending radius | ≥ 25 mm |
| Cable family | Sucofeed: Corrugated, low-loss RF cables |
| Operating frequency | ≤ 10 GHz |
| Repeated bending radius | 50 mm (bendings, up to 15) |
| Impedance | 50 Ω +/-1Ω |