GX 03272-04
Installation Temperature max. | 60°C |
Operating Temperature min. | -40°C |
Attenuation Coefficient b max. | 0.221 |
Attenuation Coefficient b | 0.201 |
Attenuation Coefficient a | 0.387 |
Attenuation Coefficient a max. | 0.426 |
Calculated Power | false |
Centre Conductor Diameter | 0.9mm |
Centre Conductor Material | Copper, Tin plated |
Conductor Inner Diameter | 0.18mm |
Installation Temperature min. | -20°C |
Operating Temperature max. | 105°C |
Outer Conductor 2 Description | Outer conductor |
Outer Conductor 3 Description | Outer conductor |
Outer Conductor 4 Description | Outer conductor |
Screen Frequency max. | 2GHz |
Screen Frequency min. | 0.04GHz |
Outer Cond1 Coverage | 96% |
Outer Conductor1 Diameter | 3.6mm |
Outer Conductor1 Material | Copper, Tin plated |
2002/96/EC (WEEE) | no special marking needed |
Class | 1148 |
2006/1907/EC (REACH) | compliant |
2000/53/EC (ELV) | compliant |
Alternative Cable | RADOX_RF_58 |
Armoring 1 Description | Armor |
Armoring 2 Description | Armor |
Armoring 3 Description | Armor |
Armoring 4 Description | Armor |
Cable Category | Flexible RF cable |
Cable Family | GX: RF cables with cross-linked PE dielectrics |
Kabelgruppe - Kabel | U7 |
Calc IL/Power up to Freq | 17MHz |
Capacitance | 101pF/m |
Centre Conductor Design | Strand-19 |
CW Power | 130W |
CW Power Frequency | 1GHz |
Description | RG58 LSFH, 50 Ohm, 3 GHz, 105°C, ø4.95 mm, RADOX® jacket, Flame retardant |
Dielectric Diameter | 2.95mm |
Dielectric Material | PEX (Polyethylene cross-linked) |
Distribution txt | RG58 LSFH, 50 Ohm, 3 GHz, 105°C, ø4.95 mm, RADOX® jacket, Flame retardant |
Dynamic Bend Radius | 100mm |
Fire Test a | IEC 60332-1 |
Fire Test b | EN 60332-1-2 |
Halogen Free | true |
Halogen Test | IEC 60754 |
ID | GX_03272-04 |
Impedance | 50Ohm |
Impedance Tolerance ± | 2Ohm |
Insulation Resistance | 100000000MOhm/m |
Jacket Colour | RAL 9005 - bk |
Jacket Diameter | 4.95mm |
Jacket Material | RADOX |
Jacket Tolerance | 0.15mm |
2011/65/EC (RoHS) | compliant |
Number of Screens | 1 |
Only as Assembly | false |
Operating Frequency | 3GHz |
Operating Voltage | 2.5kV |
Outer Conductor1 Design | Braid |
Print on Jacket | HUBER+SUHNER GX 03272-04 50 Ohm (production order number) |
Propagation Velocity | 66% of c |
Repeated Bend Radius | 50mm |
Weight | 4.04kg/100m |
Screen Effectiveness | 40dB |
Signal Delay | 5.03ns/m |
Smoke Test | EN 61034-2 |
Static Bend Radius | 25mm |
Test Voltage | 5kV |
OBJECT_ID | 7516216 |