Installation Temperature max. |
60°C |
Operating Temperature min. |
-40°C |
Attenuation Coefficient b max. |
0.221 |
Attenuation Coefficient b |
0.201 |
Attenuation Coefficient a |
0.387 |
Attenuation Coefficient a max. |
0.426 |
Calculated Power |
false |
Centre Conductor Diameter |
0.9mm |
Centre Conductor Material |
Copper, Tin plated |
Conductor Inner Diameter |
0.18mm |
Installation Temperature min. |
-20°C |
Operating Temperature max. |
105°C |
Outer Conductor 2 Description |
Outer conductor |
Outer Conductor 3 Description |
Outer conductor |
Outer Conductor 4 Description |
Outer conductor |
Screen Frequency max. |
2GHz |
Screen Frequency min. |
0.04GHz |
Outer Cond1 Coverage |
96% |
Outer Conductor1 Diameter |
3.6mm |
Outer Conductor1 Material |
Copper, Tin plated |
2002/96/EC (WEEE) |
no special marking needed |
Class |
1148 |
2006/1907/EC (REACH) |
compliant |
2000/53/EC (ELV) |
compliant |
Alternative Cable |
RADOX_RF_58 |
Armoring 1 Description |
Armor |
Armoring 2 Description |
Armor |
Armoring 3 Description |
Armor |
Armoring 4 Description |
Armor |
Cable Category |
Flexible RF cable |
Cable Family |
GX: RF cables with cross-linked PE dielectrics |
CABLE GROUP Cable |
U7 |
Calc IL/Power up to Freq |
17MHz |
Capacitance |
101pF/m |
Centre Conductor Design |
Strand-19 |
CW Power |
130W |
CW Power Frequency |
1GHz |
Description |
RG58 LSFH, 50 Ohm, 3 GHz, 105°C, ø4.95 mm, RADOX® jacket, Flame retardant |
Dielectric Diameter |
2.95mm |
Dielectric Material |
PEX (Polyethylene cross-linked) |
Distribution txt |
RG58 LSFH, 50 Ohm, 3 GHz, 105°C, ø4.95 mm, RADOX® jacket, Flame retardant |
Dynamic Bend Radius |
100mm |
Fire Test a |
IEC 60332-1 |
Fire Test b |
EN 60332-1-2 |
Halogen Free |
true |
Halogen Test |
IEC 60754 |
ID |
GX_03272-04 |
Impedance |
50Ohm |
Impedance Tolerance ± |
2Ohm |
Insulation Resistance |
100000000MOhm/m |
Jacket Colour |
RAL 9005 - bk |
Jacket Diameter |
4.95mm |
Jacket Material |
RADOX |
Jacket Tolerance |
0.15mm |
2011/65/EC (RoHS) |
compliant |
Number of Screens |
1 |
Only as Assembly |
false |
Operating Frequency |
3GHz |
Operating Voltage |
2.5kV |
Outer Conductor1 Design |
Braid |
Print on Jacket |
HUBER+SUHNER GX 03272-04 50 Ohm (production order number) |
Propagation Velocity |
66% of c |
Repeated Bend Radius |
50mm |
Weight |
4.04kg/100m |
Screen Effectiveness |
40dB |
Signal Delay |
5.03ns/m |
Smoke Test |
EN 61034-2 |
Static Bend Radius |
25mm |
Test Voltage |
5kV |
OBJECT_ID |
7516216 |