GX 03272-04
H+S | |
---|---|
Flame propagation standard | IEC 60332-1EN 60332-1-2 |
Insulation resistance | 100000000 MΩ*m |
Operation temperature | -40 °C ... 105 °C |
Fire characteristics | free of halogenes, acc. standard IEC 60754 |
Velocity of signal propagation | 66 % |
Weight | approx. 40.4 g/m |
Signal delay | 5.03 ns/m |
Screening effectiveness | 40 dB at frequency 0.04 GHz ... 2GHz |
Product code | GX_03272-04 |
Operating Voltage (at sea level) | ≤ 2.5 kVrms |
Static bending radius | ≥ 25 mm |
Cable family | GX: RF cables with cross-linked PE dielectrics |
Available as assembly only | No |
Smoke test | EN 61034-2 |
Operating frequency | ≤ 3 GHz |
Repeated bending radius | 50 mm |
Cable group | U7 |
Capacitance | 101 pF/m |
Test voltage (50 Hz/1 min) | ≤ 5 kVrms |
Installation temperature | -20 °C ... 60 °C |
Impedance | 50 Ω +/-2Ω |
Dynamic bending radius | < 100 mm |