SUCOFORM_122_LA_CU_CMP
H+S | |
---|---|
Flame propagation standard | IEC 60332-1UL 1581 § 1080 (VW-1)ETL Listed UL444/CMP/FT6 |
Insulation resistance | < 100000000 MΩ*m |
Operation temperature | -65 °C ... 165 °C |
Fire characteristics | contains halogene |
Weight | approx. 30.5 g/m |
Signal delay | 4.3 ns/m |
Screening effectiveness | 100 dB at frequency 0.1 GHz ... 18GHz |
Product code | SUCOFORM_122_LA_CU_CMP |
Operating Voltage (at sea level) | ≤ 1.9 kVrms |
Static bending radius | ≥ 5 mm |
Cable family | Sucoform: Formstable, hand-formable alternatives to semi-rigid microwave cables |
Available as assembly only | No |
Operating frequency | ≤ 6 GHz |
Repeated bending radius | 18 mm (bendings, up to 15) |
Cable group | Y31 - 122 |
Capacitance | 85 pF/m |
Test voltage (50 Hz/1 min) | ≤ 5 kVrms |
Installation temperature | -20 °C ... 60 °C |
Impedance | 50 Ω +/-2Ω |