S 07262 BD
| H+S | |
|---|---|
| Ozone test | IEC 811-2-1 - class 8 |
| Insulation resistance | 100000000 MΩ*m |
| Inner conductor resistance | 1.95 Ω/km |
| Fire characteristics | free of halogenes |
| Velocity of signal propagation | 82 % |
| Weight | approx. 206 g/m |
| Outer conductor resistance | 0.85 Ω/km |
| Signal delay | 4.1 ns/m |
| Phaase vs bending | 0.4 °/GHz |
| Product code | S_07262_BD |
| Operating Voltage (at sea level) | ≤ 1.05 kVrms |
| Available as assembly only | No |
| Cable group | S32 |
| Capacitance | 82 pF/m |
| Phase vs temperature | 2370 ppm within the temperature range -25 ... 85 °C |
| Test voltage (50 Hz/1 min) | ≤ 2.1 kVrms |
| Installation temperature | -20 °C ... 60 °C |
| Flame propagation standard | IEC 60332-1 |
| Operation temperature | -40 °C ... 85 °C |
| Screening effectiveness | 90 dB at frequency 3GHz |
| Static bending radius | 70 |
| Cable family | S: Low loss RF cables with foam PE dielectrics |
| Operating frequency | 3 |
| Repeated bending radius | 110 mm |
| Impedance | 50 Ω +/-1Ω |