RG 223 /U-60
Installation Temperature min. | -20 °C |
Description | RG223, 50 Ohm, 6 GHz, 85°C, ø5.4 mm, PVC jacket, UL AWM style 1354 |
Dielectric Diameter | 2.95 mm |
Print on Jacket | HUBER+SUHNER RG 223 U-60 50 Ohm (UL logo) AWM Style 1354 (production order number) |
Number of Screens | 2 |
Cable Family | RG: RG type RF cables |
Installation Temperature max. | 60 °C |
Dielectric Material | PE (Polyethylene) |
Operating Temperature min. | -25 °C |
Outer Conductor1 Material | Copper, Tin plated |
Temperature Rating UL | 60 °C |
Class | 1148 |
Attenuation Coefficient a max. | 0.4328 |
Attenuation Coefficient b max. | 0.0926 |
Screen Effectiveness | 85 dB |
Centre Conductor Design | Wire |
Screen Frequency min. | 0.001 GHz |
Centre Conductor Diameter | 0.88 mm |
Armoring 3 Description | Armor |
Attenuation Coefficient b | 0.0841 |
Attenuation Coefficient a | 0.3935 |
Outer Cond1 Coverage | 96 % |
Repeated Bend Radius | 54 mm |
Capacitance | 101 pF/m |
Static Bend Radius | 30 mm |
Insulation Resistance | 100000000 MOhm/m |
Outer Conductor1 Design | Braid |
Centre Conductor Material | Copper, Silver plated |
Jacket Tolerance | 0.1 mm |
Operating Temperature max. | 85 °C |
Outer Conductor2 Diameter | 4.2 mm |
Only as Assembly | N |
2006/1907/EC (REACH) | compliant |
Jacket Colour | RAL 7032 - gr |
Impedance Tolerance ± | 2 Ohm |
Cable Group | U9 |
Armoring 4 Description | Armor |
Armoring 2 Description | Armor |
Outer Conductor2 Design | Braid |
Test Voltage | 5 kV |
Outer Cond2 Coverage | 94 % |
Calculated Power | N |
Halogen Free | N |
Outer Conductor1 Diameter | 3.6 mm |
OBJECT_ID | 7516263 |
Operating Voltage | 2.5 kV |
Screen Frequency max. | 6 GHz |
Outer Conductor2 Material | Copper, Tin plated |
Outer Conductor 3 Description | Outer conductor |
Impedance | 50 Ohm |
Jacket Material | PVC (Polyvinyl chloride) |
Propagation Velocity | 66 % of c |
2011/65/EC (RoHS) | compliant |
Cable Category | Flexible RF cable |
Specification Voltage | 30 kV |
CW Power Frequency | 1 GHz |
Distribution txt | RG223, 50 Ohm, 6 GHz, 85°C, ø5.4 mm, PVC jacket, UL AWM style 1354 |
Jacket Diameter | 5.4 mm |
Outer Conductor 2 Description | Outer conductor |
Operating Frequency | 6 GHz |
CW Power | 120 W |
Outer Conductor 4 Description | Outer conductor |
Fire Test a | UL (horizontal flame test) |
Calc IL/Power up to Freq | 17 MHz |
Armoring 1 Description | Armor |
Weight | 5.5 kg/100m |
ID | RG_223_/U-60 |
Signal Delay | 5.03 ns/m |