Til toppen

HUBER+SUHNER RG 214 /U

Produktnummer: 22510057
Huber Suhner
Lagerbeholdning:

Installation Temperature max. 60 °C
Operating Temperature min. -25 °C
Attenuation Coefficient b max. 0.069
Phase vs. Temperature 19.7 °/GHz/m
Attenuation Coefficient b 0.063
Attenuation Coefficient a 0.202
Attenuation Coefficient a max. 0.222
Calculated Power N
Centre Conductor Diameter 2.25 mm
Centre Conductor Material Copper, Silver plated
Conductor Inner Diameter 0.75 mm
Inner Cond Res DC 5.8 Ohm/km
Installation Temperature min. -20 °C
Operating Temperature max. 85 °C
Outer Conductor 2 Description Outer conductor
Outer Conductor 3 Description Outer conductor
Outer Conductor 4 Description Outer conductor
Screen Frequency max. 1 GHz
Screen Frequency min. 0.001 GHz
Outer Cond Resistance DC 3.9 Ohm/km
Outer Cond1 Coverage 90.7 %
Outer Conductor1 Diameter 8 mm
Outer Conductor1 Material Copper, Silver plated
Outer Cond2 Coverage 93.9 %
Outer Conductor2 Diameter 8.7 mm
Outer Conductor2 Material Copper, Silver plated
Class 1148
2006/1907/EC (REACH) compliant
Alternative Cable S_06132_D, RG_214_U-01, RG_214_HiFlex
Armoring 1 Description Armor
Armoring 2 Description Armor
Armoring 3 Description Armor
Armoring 4 Description Armor
Bending Frequency 1 GHz
Bending Radius 110 mm
Bending Test Procedure 360
Cable Category Flexible RF cable
Cable Family RG: RG type RF cables
Cable Group U32
Calc IL/Power up to Freq 17 MHz
Capacitance 101 pF/m
Centre Conductor Design Strand-07
CW Power 325 W
CW Power Frequency 1 GHz
Description RG214, 50 Ohm, 6 GHz, 85°C, ø10.8 mm, PVC jacket
Dielectric Diameter 7.28 mm
Dielectric Material PE (Polyethylene)
Distribution txt RG214, 50 Ohm, 6 GHz, 85°C, ø10.8 mm, PVC jacket
Halogen Free N
ID RG_214_/U
Impedance 50 Ohm
Impedance Tolerance ± 1 Ohm
Insulation Resistance 100000000 MOhm/m
Jacket Colour RAL 9005 - bk
Jacket Diameter 10.8 mm
Jacket Material PVC II (low migration)
Jacket Tolerance 0.15 mm
2011/65/EC (RoHS) compliant
Number of Cycles 50
Number of Screens 2
Only as Assembly N
Operating Frequency 6 GHz
Operating Voltage 5 kV
Outer Conductor1 Design Braid
Outer Conductor2 Design Braid
Phase Temperature max. 70 °C
Phase Temperature min. -40 °C
Phase vs. Bending 9 °/GHz
Print on Jacket HUBER+SUHNER RG 214 U 50 Ohm (production order number)
Propagation Velocity 66 % of c
Repeated Bend Radius 108 mm
Weight 18.5 kg/100m
Screen Effectiveness 71 dB
Signal Delay 5 ns/m
Static Bend Radius 55 mm
Test Voltage 10 kV
OBJECT_ID 7516254
Espen Johannessen
Business Area Manager Contract manufacturers and Wholesalers Vis telefon Vis e-post