3407.41.0051
H+S | |
---|---|
Side of bulkhead | protected side |
Gas tube | No DC / shorted QW or LC |
PIM 3rd order | -150 dBc typ. , -155 dBc typ. |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Power avg. / peak | 500 W / - |
Vibration according | MIL-STD-202, Method 204, Cond. A |
Insertion loss | 0.1 dB |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 0.03 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Product description | Quarter-wave stub technology with integrated high-pass filter |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
Insertion loss typical | 0.1 dB |
Product code | 3407.41.0051 |
Main path connectors | Port 1: unprotected, 7/16 plug (male)Port 2: protected, 7/16 jack (female) |
Housing material / plating | Brass / SUCOPLATE (R) Plating |
Ingress protection (IP Rating) | Mated / IP67, according to IEC 60529 |
Frequency frame | 690 MHz to 2700 MHz |
Mounting and grounding | MH110 (bulkhead mounting), M6 (screw) |
Return loss typical | 23 dB , 26 dB |
Surge current handling capability | 25 kA single, 20 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Brass / Silver PlatingPort 2: Bronze / Silver Plating |
EMP can be install reversed | YES |
Frequency range | 690 MHz ... 2500 MHz |
Mating cycles | 500 |
CW power frame | 500 W |
Inline design | YES |
Weight | 430 g |