H+S |
Side of bulkhead |
protected side |
PIM 3rd order |
-150 dBc typ. , -155 dBc typ. |
Moisture resistance according |
MIL-STD-202, Method 106 |
Power avg. / peak |
500 W / - |
Vibration according |
MIL-STD-202, Method 204, Cond. A |
Insertion loss |
0.1 dB |
bre.att-ter-frequency-range-max |
2700 |
bre.att-ter-frequency-range-min |
690 |
Storage temperature |
-40 °C ... 85 °C |
Residual pulse energy (typ.) |
0.03 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Thermal shock according |
MIL-STD-202, Method 107, Cond. B |
Insertion loss typical |
0.1 dB |
Product code |
3407.41.0051 |
Main path connectors |
Port 1: unprotected, 7/16 plug (male)Port 2: protected, 7/16 jack (female) |
Housing material / plating |
Brass / SUCOPLATE (R) Plating |
Ingress protection (IP Rating) |
Mated / IP67, according to IEC 60529 |
Details |
CAS: 7439-92-1 Lead |
Mounting and grounding |
MH110 (bulkhead mounting), M6 (screw) |
Return loss typical |
23 dB , 26 dB |
Surge current handling capability |
25 kA single, 20 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating |
Port 1: Brass / Silver PlatingPort 2: Bronze / Silver Plating |
EMP can be install reversed |
YES |
Frequency range |
690 MHz ... 2500 MHz |
Mating cycles |
500 |
Inline design |
YES |
Weight |
430 g |
Exemptions |
6c |
Gas tube |
No DC / shorted QW or LC |
Directive |
RoHS 2011/65/EU and (EU) 2015/863 |
Impedance |
50 Ω |
Operation temperature |
-40 °C ... 85 °C |
Rating |
Compliant with exemption , Contains one or more SVHC >0,1% |
Product description |
Quarter-wave stub technology with integrated high-pass filter |
Frequency frame |
690 MHz to 2700 MHz |
Regulation |
REACH 1907/2006 Article 33 SVHC |
CW power frame |
500 |