Skip to main content
Til toppen

G 03262 D

Produktnummer: 22511812
Huber Suhner
Lagerbeholdning:

H+S
Flame propagation standard IEC 60332-1UL 1581 § 1080 (VW-1)
Insulation resistance 100000000 MΩ*m
Operation temperature -40 °C ... 85 °C
Inner conductor resistance 27.7 Ω/km
Fire characteristics free of halogenes, acc. standard IEC 60754
Velocity of signal propagation 66 %
Weight approx. 55 g/m
Outer conductor resistance 6.7 Ω/km
Signal delay 5.03 ns/m
Screening effectiveness 80 dB at frequency 0.001 GHz ... 1GHz
Product code G_03262_D
Operating Voltage (at sea level) ≤ 2.5 kVrms
Static bending radius ≥ 27 mm
Cable family G: RF cables with PE dielectrics
Available as assembly only No
Operating frequency ≤ 6 GHz
Repeated bending radius 55 mm
Cable group U9
Capacitance 101 pF/m
Test voltage (50 Hz/1 min) ≤ 5 kVrms
Installation temperature -20 °C ... 60 °C
Impedance 50 Ω +/-2Ω