G 02262
| H+S | |
|---|---|
| Insulation resistance | 100000000 MΩ*m |
| Fire characteristics | free of halogenes, acc. standard IEC 60754 |
| Velocity of signal propagation | 66 % |
| Weight | approx. 13.3 g/m |
| Signal delay | 5.03 ns/m |
| Product code | G_02262 |
| Operating Voltage (at sea level) | ≤ 1.5 kVrms |
| Available as assembly only | No |
| Cable group | U2 |
| Capacitance | 101 pF/m |
| Test voltage (50 Hz/1 min) | ≤ 3 kVrms |
| Installation temperature | -20 °C ... 60 °C |
| Noise level | 10 mV |
| Flame propagation standard | IEC 60332-1 |
| Operation temperature | -40 °C ... 85 °C |
| Screening effectiveness | 38 dB at frequency 0.001 GHz ... 1GHz |
| Static bending radius | 15 |
| Cable family | G: RF cables with PE dielectrics |
| Operating frequency | 1 |
| Repeated bending radius | 28 mm |
| Impedance | 50 Ω +/-2Ω |