ENVIROFLEX_B316_D
H+S | |
---|---|
Flame propagation standard | IEC 60332-1 |
Insulation resistance | 10000000 MΩ*m |
Operation temperature | -40 °C ... 85 °C |
Inner conductor resistance | 269 Ω/km |
Fire characteristics | free of halogenes |
Velocity of signal propagation | 71 % |
Weight | approx. 19 g/m |
Outer conductor resistance | 17 Ω/km |
Signal delay | 4.7 ns/m |
Screening effectiveness | 60 dB at frequency 1 GHz ... 6GHz |
Product code | Enviroflex_B316_D |
Operating Voltage (at sea level) | ≤ 1.3 kVrms |
Static bending radius | ≥ 5 mm |
Cable family | Enviroflex: LSFH alternatives to RG cables |
Available as assembly only | No |
Thermal stress test | IEC 61196-1 § 10.9 |
Operating frequency | ≤ 6 GHz |
Repeated bending radius | 30 mm |
Cable group | U4 |
Capacitance | 94.5 pF/m |
Cold bend test | MIL-C-17 § 4.8.19 |
Test voltage (50 Hz/1 min) | ≤ 3 kVrms |
Installation temperature | -20 °C ... 60 °C |
Impedance | 50 Ω +/-2Ω |
Dynamic bending radius | < 30 mm |