EF 316 D-01
| H+S | |
|---|---|
| UV resistance | IEC 60068-2-5, proc. C |
| Fire characteristics | free of halogenes, acc. standard IEC 60754 |
| Velocity of signal propagation | 70.1 % |
| Weight | approx. 21 g/m |
| Signal delay | 4.72 ns/m |
| Product code | ENVIROFLEX_316_D-01 |
| Ageing test | MIL-C-17 § 4.8.16 |
| Operating Voltage (at sea level) | ≤ 1.3 kVrms |
| Abrasion test | MIL-T-81490 - §4.7.19 - prod. II - modified |
| Available as assembly only | No |
| Thermal stress test | IEC 61196-1 § 10.9 |
| Smoke test | EN 61034-2 |
| Voltage Rating UL | 300 V |
| Cable group | U4 |
| Capacitance | 94.5 pF/m |
| Cold bend test | MIL-C-17 § 4.8.19 |
| Test voltage (50 Hz/1 min) | ≤ 3 kVrms |
| Installation temperature | -20 °C ... 60 °C |
| Dynamic bending radius | ≤ 30 mm |
| Directive | RoHS 2011/65/EU and (EU) 2015/863 |
| Flame propagation standard | EN 60332-1-2UL 1581 § 1100 |
| Operation temperature | -40 °C ... 105 °C |
| Rating | Compliant without exemption , Free of SVHC >0,1% |
| Static bending radius | 5 |
| Cable family | Enviroflex: LSFH alternatives to RG cables |
| Operating frequency | 6 |
| Repeated bending radius | 30 mm (bendings, up to 3000) |
| Impedance | 50 Ω +/-2Ω |
| Regulation | REACH 1907/2006 Article 33 SVHC |