3400.17.0416
| H+S | |
|---|---|
| PIM 3rd order | 0 dBc |
| Moisture resistance according | MIL-STD-202, Method 106 |
| Power avg. / peak | 750 W / - 450 W / - |
| Vibration according | MIL-STD-202, Method 204, Cond. A |
| bre.att-ter-frequency-range-max | 2900 |
| Insertion loss | 0.10.1 dB |
| bre.att-ter-frequency-range-min | 1000 |
| Storage temperature | -40 °C ... 85 °C |
| Residual pulse energy (typ.) | 5 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
| Thermal shock according | MIL-STD-202, Method 107, Cond. B |
| Product code | 3400.17.0416 |
| Main path connectors | Port 1: unprotected, N jack (female)Port 2: protected, N jack (female) |
| Housing material / plating | Brass / SUCOPLATE (R) Plating |
| Ingress protection (IP Rating) | IP65 |
| Mounting and grounding | MH25 (bulkhead mounting), M8 (screw) |
| Surge current handling capability | 50 kA multiple (test pulse 8/20 µs) |
| Center contact, material / plating | Port 1: Copper Beryllium Alloy / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
| EMP can be install reversed | YES |
| Frequency range | 1000 MHz ... 1100 MHz2700 MHz ... 2900 MHz |
| Return loss typical | 2020 dB |
| Mating cycles | 500 |
| Weight | 300 g |
| Exemptions | 6c |
| Gas tube | No DC / shorted QW or LC |
| Directive | RoHS 2011/65/EU and (EU) 2015/863 |
| Impedance | 50 Ω |
| Operation temperature | -40 °C ... 85 °C |
| Rating | Compliant with exemption |
| Product description | Quarter-wave stub technology |
| Frequency frame | 1000 MHz to 2900 MHz |