RADOX_RF_213

SKU: 85023730
Huber Suhner
Stock:

H+S
Flame propagation standard EN 60332-1-2IEC 60332-3-25
UV resistance ISO 4892-2A
Insulation resistance 10000000 MΩ*m
Operation temperature -40 °C ... 105 °C
Fire characteristics free of halogenes, acc. standard IEC 60754
Velocity of signal propagation 66 %
Weight approx. 168 g/m
Signal delay 5.03 ns/m
Screening effectiveness 41 dB at frequency 0.001 GHz ... 2GHz
Product code RADOX_RF_213
Operating Voltage (at sea level) ≤ 5 kVrms
Static bending radius ≥ 50 mm
Cable family RADOX RF: Highly flame retardant LSFH alternatives to RG cables
Available as assembly only No
Smoke test EN 61034-2
Operating frequency ≤ 2 GHz
Repeated bending radius 100 mm (bendings, up to 50)
Cable group U42
Capacitance 101 pF/m
Test voltage (50 Hz/1 min) ≤ 10 kVrms
Installation temperature -20 °C ... 60 °C
Impedance 50 Ω +/-2Ω
Dynamic bending radius < 150 mm
Glenn Barmen
Business Area Manager Maritime Show phone Show e-mail
Links
Language