3407.17.0053
| H+S | |
|---|---|
| Side of bulkhead | protected side |
| Moisture resistance according | MIL-STD-202, Method 106 |
| Vibration according | MIL-STD-202, Method 204, Cond. A |
| bre.att-ter-frequency-range-max | 512 |
| bre.att-ter-frequency-range-min | 320 |
| Storage temperature | -40 °C ... 85 °C |
| Residual pulse energy (typ.) | 0.03 µJ LEMP (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs)265 µJ NEMP (test pulse 6 kV 5/200 ns) |
| Thermal shock according | MIL-STD-202, Method 107, Cond. B |
| Insertion loss typical | ≤ 0.2 dB |
| Product code | 3407.17.0053 |
| Main path connectors | Port 1: unprotected, N plug (male)Port 2: protected, N jack (female) |
| Housing material / plating | Brass / SUCOPLATE (R) Plating |
| Ingress protection (IP Rating) | Mated / IP65, according to IEC 60529 |
| Mounting and grounding | MH12 (bulkhead mounting), M8 (screw), brk (bracket) |
| Residual pulse voltage (typ.) | 2050 V NEMP (test pulse 6 kV 5/200 ns) |
| Return loss typical | ≥ 20 dB |
| Surge current handling capability | 50 kA multiple (test pulse 8/20 µs) |
| Center contact, material / plating | Port 1: Brass / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
| EMP can be install reversed | YES |
| Mating cycles | 500 |
| Weight | 320 g |
| Exemptions | 6c |
| Gas tube | No DC / shorted QW or LC |
| Directive | RoHS 2011/65/EU and (EU) 2015/863 |
| Impedance | 50 Ω |
| Operation temperature | -40 °C ... 85 °C |
| Rating | Compliant with exemption |
| Product description | Quarter-wave stub technology with integrated high-pass filter |
| Frequency frame | 320 MHz to 512 MHz |
| CW power frame | 500 |