3407.17.0053
H+S | |
---|---|
Side of bulkhead | protected side |
Gas tube | No DC / shorted QW or LC |
Directive | RoHS 2011/65/EU and (EU) 2015/863 |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Vibration according | MIL-STD-202, Method 204, Cond. A |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 0.03 µJ LEMP (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs)265 µJ NEMP (test pulse 6 kV 5/200 ns) |
Rating | Compliant with exemption |
Product description | Quarter-wave stub technology with integrated high-pass filter |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
Insertion loss typical | ≤ 0.2 dB |
Product code | 3407.17.0053 |
Main path connectors | Port 1: unprotected, N plug (male)Port 2: protected, N jack (female) |
Housing material / plating | Brass / SUCOPLATE (R) Plating |
Ingress protection (IP Rating) | Mated / IP65, according to IEC 60529 |
Frequency frame | 320 MHz to 512 MHz |
Mounting and grounding | MH12 (bulkhead mounting), M8 (screw), brk (bracket) |
Residual pulse voltage (typ.) | 2050 V NEMP (test pulse 6 kV 5/200 ns) |
Return loss typical | ≥ 20 dB |
Surge current handling capability | 50 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Brass / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
EMP can be install reversed | YES |
Mating cycles | 500 |
CW power frame | ≤ 500 W |
Weight | 320 g |
Exemptions | 6c |