K 01152-07
H+S | |
---|---|
Flame propagation standard | IEC 60332-3UL (horizontal flame test) |
Insulation resistance | 100000000 MΩ*m |
Operation temperature | -80 °C ... 205 °C |
Fire characteristics | contains halogene |
Velocity of signal propagation | 69 % |
Weight | approx. 9 g/m |
Signal delay | 4.83 ns/m |
Screening effectiveness | 40 dB at frequency 0.001 GHz ... 1GHz |
Product code | K_01152-07 |
Operating Voltage (at sea level) | ≤ 0.4 kVrms |
Static bending radius | ≥ 6 mm |
Cable family | K: RF cables with PTFE/FEP/PFA dielectrics |
Available as assembly only | No |
Operating frequency | ≤ 1 GHz |
Repeated bending radius | 12 mm |
Cable group | U0 |
Capacitance | 96.6 pF/m |
Test voltage (50 Hz/1 min) | ≤ 0.8 kVrms |
Installation temperature | -20 °C ... 60 °C |
Impedance | 50 Ω +/-5Ω |
Dynamic bending radius | < 20 mm |