3403.26.0002
| H+S | |
|---|---|
| Side of bulkhead | protected side |
| Moisture resistance according | MIL-STD-202, Method 106 |
| Vibration according | MIL-STD-202, Method 204, Cond. A |
| Insertion loss | ≤ 0.3 dB |
| bre.att-ter-frequency-range-max | 2500 |
| bre.att-ter-frequency-range-min | 800 |
| Storage temperature | -40 °C ... 85 °C |
| Residual pulse energy (typ.) | 6 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
| Thermal shock according | MIL-STD-202, Method 107, Cond. B |
| DC supply voltage | 6 V |
| Insertion loss typical | ≤ 0.3 dB |
| Product code | 3403.26.0002 |
| Main path connectors | Port 1: unprotected, TNC jack (female)Port 2: protected, TNC jack (female) |
| Housing material / plating | Aluminium / Chromatized |
| Ingress protection (IP Rating) | Mated / IP67, according to IEC 60529 |
| Details | CAS: 7439-92-1 Lead |
| Mounting and grounding | MH12 (bulkhead mounting) |
| Residual pulse voltage (typ.) | 8 V (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
| Return loss typical | ≥ 23 dB , ≥ 26.44 dB |
| Surge current handling capability | 20 kA single (test pulse 8/20 µs) |
| Center contact, material / plating | Port 1: Copper Beryllium Alloy / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
| Frequency range | 1500 MHz ... 1700 MHz |
| DC current | 3 A |
| Mating cycles | 100 |
| Weight | 90 g |
| Exemptions | 6c |
| Gas tube | Yes DC, GDT included, not replaceable |
| Directive | RoHS 2011/65/EU and (EU) 2015/863 |
| Impedance | 50 Ω |
| Operation temperature | -40 °C ... 85 °C |
| Rating | Compliant with exemption , Contains one or more SVHC >0,1% |
| Product description | Fine protector hybrid technology |
| Frequency frame | 800 MHz to 2500 MHz |
| Regulation | REACH 1907/2006 Article 33 SVHC |
| CW power frame | 50 |