RG 214 HI-FLEX
| H+S | |
|---|---|
| Insulation resistance | 100000000 MΩ*m |
| Fire characteristics | contains halogene |
| Velocity of signal propagation | 66 % |
| Weight | approx. 185 g/m |
| Outer conductor resistance | 3.9 Ω/km |
| Signal delay | 5.03 ns/m |
| Phaase vs bending | 5 °/GHz |
| Product code | RG_214_HIFLEX |
| Operating Voltage (at sea level) | ≤ 5 kVrms |
| Available as assembly only | No |
| Cable group | U32 |
| Capacitance | 101 pF/m |
| Phase vs temperature | 16200 ppm within the temperature range -40 ... 80 °C |
| Test voltage (50 Hz/1 min) | ≤ 10 kVrms |
| Installation temperature | -20 °C ... 60 °C |
| Dynamic bending radius | < 100 mm |
| Directive | RoHS 2011/65/EU and (EU) 2015/863 |
| Flame propagation standard | IEC 60332-1 |
| Operation temperature | -25 °C ... 85 °C |
| Rating | Compliant without exemption , Free of SVHC >0,1% |
| Screening effectiveness | 70 dB at frequency 0.001 GHz ... 1GHz |
| Static bending radius | 15 |
| Cable family | RG: RG type RF cables |
| Operating frequency | 6 |
| Repeated bending radius | 60 mm |
| Impedance | 50 Ω +/-2Ω |
| Regulation | REACH 1907/2006 Article 33 SVHC |