G 03212 D-01
H+S | |
---|---|
Insulation resistance | 100000000 MΩ*m |
Inner conductor resistance | 38.6 Ω/km |
Fire characteristics | free of halogenes, acc. standard IEC 60754 |
Velocity of signal propagation | 66 % |
Weight | approx. 53 g/m |
Signal delay | 5.03 ns/m |
Product code | G_03212_D-01 |
Operating Voltage (at sea level) | ≤ 2.5 kVrms |
Available as assembly only | No |
Cable group | U9 |
Capacitance | 100.7 pF/m |
Test voltage (50 Hz/1 min) | ≤ 5 kVrms |
Installation temperature | -20 °C ... 60 °C |
Directive | RoHS 2011/65/EU and (EU) 2015/863 |
Operation temperature | -40 °C ... 85 °C |
Rating | Compliant without exemption , Free of SVHC >0,1% |
Screening effectiveness | 80 dB at frequency 0.001 GHz ... 6GHz |
Static bending radius | 30 |
Cable family | G: RF cables with PE dielectrics |
Operating frequency | 6 |
Repeated bending radius | 55 mm |
Impedance | 50 Ω +/-2Ω |
Regulation | REACH 1907/2006 Article 33 SVHC |