9077.17.0030
H+S | |
---|---|
Side of bulkhead | Port 2 |
PIM 3rd order | -150 dBc typ. , -150 dBc |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Power avg. / peak | ≤500 W / ≤1000 W |
Vibration according | MIL-STD-202, Method 204, Cond. D |
Insertion loss | ≤ 0.1 dB |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Product description | Broadband HIGH VOLTAGE DC-DC Block |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
Galvanic isolation outer conductor | Yes |
Insertion loss typical | ≤ 0.2 dB |
Product code | 9077.17.0030 |
Main path connectors | Port 1: N plug (male)Port 2: N jack (female) |
Housing material / plating | POM (Polyoxymethylene) |
Electrical remarks | The voltage test is conducted at 5000 V DC for 1 minute including transient. |
Galvanic isolation inner conductor | Yes |
Ingress protection (IP Rating) | Mated / IP65, according to IEC 60529 |
Leakage current | ≤ 5 µA |
Test voltage | 5000 V |
Blocking voltage outer conductor | ≤ 4000 V DC |
Frequency frame | 160 MHz to 3000 MHz |
Mounting and grounding | MH110 (bulkhead mounting) |
Return loss typical | ≥ 22 dB , ≥ 26.44 dB |
Center contact, material / plating | Port 1: Brass / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
Frequency range | 300 MHz ... 2500 MHz |
Blocking voltage center conductor | ≤ 4000 V DC |
Test leakage current max | 10 µA |
Peak power frame | ≤ 1000 W |
CW power frame | ≤ 500 W |
Weight | 483 g |