3400.41.0216
H+S | |
---|---|
Gas tube | No DC / shorted QW or LC |
PIM 3rd order | -150-150 dBc typ. |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Power avg. / peak | 3000 W / 20000 W 1500 W / 20000 W |
Vibration according | MIL-STD-202, Method 204, Cond. A |
Insertion loss | 0.150.15 dB |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 10 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs) |
Product description | Quarter-wave stub technology |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
Insertion loss typical | 0.15 dB |
Product code | 3400.41.0216 |
Main path connectors | Port 1: unprotected, 7/16 jack (female)Port 2: protected, 7/16 jack (female) |
Housing material / plating | Brass / SUCOPLATE (R) Plating |
Ingress protection (IP Rating) | IP65 |
Frequency frame | 806 MHz to 2500 MHz |
Mounting and grounding | M8 (screw), brk (bracket) |
Return loss typical | 20.8 dB , 2626 dB |
Surge current handling capability | 80 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Copper Beryllium Alloy / Silver PlatingPort 2: Copper Beryllium Alloy / Silver Plating |
EMP can be install reversed | YES |
Frequency range | 806 MHz ... 960 MHz1710 MHz ... 2500 MHz |
Mating cycles | 500 |
Peak power frame | 20000 W |
CW power frame | 1500 W |
Weight | 376 g |