EF 400
Enviroflex 400 - halogenfri koaksialkabel
| H+S | |
|---|---|
| Toxicity test | NF X 70-100 |
| UV resistance | IEC 60068-2-5, proc. C |
| Insulation resistance | 10000000 MΩ*m |
| Inner conductor resistance | 29.45 Ω/km |
| Fire characteristics | free of halogenes, acc. standard IEC 60754 |
| Velocity of signal propagation | 70.3 % |
| Weight | approx. 60 g/m |
| Outer conductor resistance | 7.6 Ω/km |
| Signal delay | 4.74 ns/m |
| Phaase vs bending | 0.5 °/GHz |
| Product code | ENVIROFLEX_400 |
| CPR class | Eca |
| Ageing test | MIL-C-17 § 4.8.16 |
| Operating Voltage (at sea level) | ≤ 2.5 kVrms |
| Abrasion test | MIL-T-81490 - §4.7.19 - prod. II - modified |
| Available as assembly only | No |
| Thermal stress test | IEC 61196-1 § 10.9 |
| Smoke test | EN 61034-2 |
| Voltage Rating UL | 300 V |
| Cable group | U11 |
| Capacitance | 94 pF/m |
| Cold bend test | MIL-C-17 § 4.8.19 |
| Phase vs temperature | 10000 ppm within the temperature range -40 ... 100 °C |
| Test voltage (50 Hz/1 min) | ≤ 5 kVrms |
| Installation temperature | -20 °C ... 60 °C |
| Dynamic bending radius | < 40 mm |
| Directive | RoHS 2011/65/EU and (EU) 2015/863 |
| Flame propagation standard | EN 60332-1-2UL 1581 § 1100IEC 60332-1 |
| Operation temperature | -40 °C ... 105 °C |
| Rating | Compliant without exemption |
| Screening effectiveness | 70 dB at frequency 0.001 GHz ... 6GHz |
| Static bending radius | 10 |
| Cable family | Enviroflex: LSFH alternatives to RG cables |
| Operating frequency | 6 |
| Repeated bending radius | 40 mm |
| Impedance | 50 Ω +/-2Ω |