EF 316
H+S | |
---|---|
UV resistance | IEC 60068-2-5, proc. C |
Fire characteristics | free of halogenes, acc. standard IEC 60754 |
Velocity of signal propagation | 70.7 % |
Weight | approx. 16 g/m |
Signal delay | 4.71 ns/m |
Product code | ENVIROFLEX_316 |
Ageing test | MIL-C-17 § 4.8.16 |
Operating Voltage (at sea level) | ≤ 1.5 kVrms |
Available as assembly only | No |
Voltage Rating UL | 300 V |
Capacitance | 94.5 pF/m |
Cold bend test | MIL-C-17 § 4.8.19 |
Test voltage (50 Hz/1 min) | ≤ 3 kVrms |
Installation temperature | -20 °C ... 60 °C |
Dynamic bending radius | ≤ 30 mm |
Directive | RoHS 2011/65/EU and (EU) 2015/863 |
Flame propagation standard | UL 1581 § 1100 |
Operation temperature | -40 °C ... 105 °C |
Rating | Compliant without exemption |
Static bending radius | 5 |
Cable family | Enviroflex: LSFH alternatives to RG cables |
Operating frequency | 3 |
Repeated bending radius | 25 mm (bendings, up to 3000) |
Impedance | 50 Ω +/-2Ω |