RG_22_B/U-05
Jacket Thickness | 0.9 mm |
1st Dielectric Material | PE (Polyethylene) |
1st Centre Cond Design | Strand-07 |
Installation Temperature max. | 60 °C |
2nd Dielectric Material | PE (Polyethylene) |
2nd Centre Cond Design | Strand-07 |
1st Dielectric Diameter | 2.25 |
Operating Temperature min. | -40 °C |
2nd Centre Cond. Material | Copper, Tin plated |
1st Centre Conductor Diameter | 1.2 mm |
1st Centre Cond. Material | Copper |
Epsilon r | 2.28 |
2nd Centre Conductor Diameter | 1.2 mm |
2nd Dielectric Diameter | 2.25 mm |
Calculated Power | N |
Installation Temperature min. | -20 °C |
Operating Temperature max. | 85 °C |
Outer Conductor 2 Description | Outer conductor |
Outer Cond1 Coverage | 94 % |
Outer Conductor1 Diameter | 8.2 mm |
Outer Conductor1 Material | Copper, Tin plated |
Outer Cond2 Coverage | 95 % |
Outer Conductor2 Diameter | 8.9 mm |
Outer Conductor2 Material | Copper, Tin plated |
2002/96/EC (WEEE) | no special marking needed |
Class | 1148 |
2006/1907/EC (REACH) | compliant |
2000/53/EC (ELV) | compliant |
Cable Category | Twinaxial cable |
Cable Family | RG: RG type RF cables |
Kabelgruppe - Kabel | U99 |
Calc IL/Power up to Freq | 17 MHz |
Capacitance | 53 pF/m |
Cold Bend Test | MIL-C-17 § 4.8.19 |
Description | RG22 twinax, 95 Ohm, 0.2 GHz, 85°C, ø10.7 mm, RADOX® jacket, Flame retardant, Railway qualified |
Dielectric Diameter | 7.25 mm |
Dielectric Material | PE (Polyethylene) |
Distribution txt | RG22 twinax, 95 Ohm, 0.2 GHz, 85°C, ø10.7 mm, RADOX® jacket, Flame retardant, Railway qualified |
Dynamic Bend Radius | 220 mm |
Fire Test a | IEC 60332-1 |
Fire Test b | IEC 60332-3-25 |
Halogen Free | 1 |
Halogen Test | IEC 60754 |
ID | RG_22_B/U-05 |
Impedance | 95 Ohm |
Impedance Tolerance ± | 5 Ohm |
Insulation Resistance | 100000000 MOhm/m |
Jacket Colour | RAL 3027 - rd |
Jacket Diameter | 10.7 mm |
Jacket Material | RADOX EM104 |
Jacket Tolerance | 0.2 mm |
2011/65/EC (RoHS) | compliant |
Number of Screens | 2 |
Only as Assembly | N |
Operating Frequency | 0.2 GHz |
Operating Voltage | 1 kV |
Outer Conductor1 Design | Braid |
Outer Conductor2 Design | Braid |
Print on Jacket | HUBER+SUHNER RG 22 B/U-05 LUL 95 Ohm (production order number) |
Propagation Velocity | 66.5 % of c |
Repeated Bend Radius | 110 mm |
Weight | 17.6 kg/100m |
Smoke Test | EN 61034-2 |
Static Bend Radius | 55 mm |
Test Voltage | 2 kV |
OBJECT_ID | 7516259 |