12-12E9A2/W(ZNG)R-G85 (DNV)
Mechanical Thermal Properies | High abrasion and soldering iron resistance |
Water penetr Standard | IEC 60794-1-2 F5B |
Cable Type | Metal free rodent-protected indoor and outdoor cable |
Cable Description | Multi-fiber Loose Tube Cable |
Outer Jacket Type | Outer jacket / RADOX |
Impact Standard | IEC 60794-1-2 E4 |
Tension Test Standard | IEC 60794-1-2 E1 |
Strain Reliefed Armouring | High flexibility and form stability |
OBJECT_ID | 8182638 |
Wavelength | for singlemode at 1550nm, for multimode at 1300nm |
Fire Standard Single | IEC 60332-1-2 |
Outer Jacket Ø | 8.5mm |
Class | 1032 |
Reinforcement Type | Reinforcement / glass-roving |
Temperature Standard | IEC 60794-1-2 F1 |
Number of max. Fibres | 24 |
Crush Test Standard | IEC 60794-1-2 E3 |
Fire Standard Bundle | IEC 60332-3-25 |
Tube Type | Multi-fiber loose tube, up to 24 fibers each |
Fire Standard Circuit | IEC 60331-25 |
Installation | UV and Ozone resistance |
Other Properties | Meets requirements for circuit integrity in case of fire |
Comments | Meets LSFH properties RADOX® jacket material compliant to EM 104 specification of EN 50264-1 for railway rolling stock application Fully compliant to CEN/TS 45545-2 for fire safety in railway applications Fulfills the flame, fire, oil and drilling fluid resistance acc. NEK 606 NEK 606 standard for offshore oil and gas, ship and marine applications Application acc. NEK 606: outdoor cable for emergency systems - operational during fire Compliant to EN 45545 / hazard level 3 |
ID | 24-.../W(ZNG)R-...85 |
Other Properties2 | Best oil and fluid resistance |
Fire Behavior | Halogen free cable with improved behaviour in case of fire |