3407.41.0038
H+S | |
---|---|
Moisture resistance according | MIL-STD-202, Method 106 |
Vibration according | MIL-STD-202, Method 204, Cond. A |
bre.att-ter-frequency-range-max | 512 |
bre.att-ter-frequency-range-min | 380 |
Storage temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 0.03 µJ LEMP (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs)120 µJ NEMP (test pulse 6 kV 5/200 ns) |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
Insertion loss typical | ≤ 0.2 dB |
Product code | 3407.41.0038 |
Main path connectors | Port 1: unprotected, 7/16 plug (male)Port 2: protected, 7/16 jack (female) |
Housing material / plating | Brass / SUCOPLATE (R) Plating |
Ingress protection (IP Rating) | Mated / IP65, according to IEC 60529 |
Mounting and grounding | M8 (screw), brk (bracket) |
Residual pulse voltage (typ.) | 455 V NEMP (test pulse 6 kV 5/200 ns) |
Return loss typical | ≥ 20 dB |
Surge current handling capability | 80 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Brass / Silver PlatingPort 2: Copper Beryllium Alloy / Silver Plating |
EMP can be install reversed | YES |
Weight | 430 g |
Exemptions | 6c |
Gas tube | No DC / shorted QW or LC |
Directive | RoHS 2011/65/EU and (EU) 2015/863 |
Impedance | 50 Ω |
Operation temperature | -40 °C ... 85 °C |
Rating | Compliant with exemption |
Product description | Quarter-wave stub technology with integrated high-pass filter |
Frequency frame | 380 MHz to 512 MHz |
CW power frame | 500 |