3407.17.0085
H+S | |
---|---|
Side of bulkhead | protected side |
Gas tube | No DC / shorted QW or LC |
Moisture resistance according | MIL-STD-202, Method 106 |
Impedance | 50 Ω |
Vibration according | MIL-STD-202, Method 204, Cond. A |
Storage temperature | -40 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Residual pulse energy (typ.) | 0.1 nJ LEMP (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs)20 nJ (test pulse 55 kA 8/20 µs) |
Product description | Quarter-wave stub technology with integrated high-pass filter |
Thermal shock according | MIL-STD-202, Method 107, Cond. B |
Insertion loss typical | ≤ 0.2 dB |
Product code | 3407.17.0085 |
Main path connectors | Port 1: unprotected, N plug (male)Port 2: protected, N jack (female) |
Housing material / plating | Aluminium / Chromatized |
Ingress protection (IP Rating) | Mated / IP68, according to IEC 60529 |
Frequency frame | 2000 MHz to 6000 MHz |
Mounting and grounding | MH170 (bulkhead mounting), brk (bracket) |
Residual pulse voltage (typ.) | 0.5 V LEMP (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs)5 V (test pulse 55 kA 8/20 µs) |
Return loss typical | ≥ 20 dB |
Surge current handling capability | 50 kA multiple (test pulse 8/20 µs) |
Center contact, material / plating | Port 1: Brass / Gold Plating (without Nickel underplating)Port 2: Copper Beryllium Alloy / Gold Plating (without Nickel underplating) |
EMP can be install reversed | YES |
Mating cycles | 100 |
CW power frame | ≤ 300 W |
Inline design | YES |
Weight | 108 g |