1399.99.0032
H+S | |
---|---|
Radome material | ASA (acrylic ester-styrene-acrylonitrile) |
Ingress protection (IP Rating) | Mated / IP67, IP69 |
Dimensions | 40 mm x 100 mm x 145 mm (Height x Width x Depth) |
Windload | Wind Speed survival: 500 km/h |
Environment (application) | Outdoor |
Back plate/base plate material | Aluminum |
Remarks | For further information please refer to data sheet. , Indicated VSWR values are valid for a metallic ground plane of 0.2 x 0.2m or larger. Indicated gain values will be achieved on a metallic ground plane of 1 x 1 m or larger.High-voltage-protection: no voltage on RF port, if catenary line touches antenna (EN 50124-1, 24 kVAC/1min).High-current-protection: Designed acc. to UIC 533, DC-grounded antenna element protection against lightning and short circuit with catenary lines (EN50388, EN 50122-1, 40kA/0.1sec) , Corrosion Low corrosion design acc. to MIL-F-14072(E).Mounting Shall be installed in longitudinal position to the wind/driving direction.Suitable for installation on high speed trains with a maximum speed of 500 km/hr.4x composite sealing washers included for silicone-free sealing of the mounting screws |
Radome colour | RAL 7043 (dark grey) |
Solar radiation | DIN 75220 |
Bands | 790 MHz ... 806 MHz, VSWR 2.2, Gain 5 dBi806 MHz ... 870 MHz, VSWR 1.8, Gain 5 dBi870 MHz ... 960 MHz, VSWR 1.5, Gain 5 dBi1350 MHz ... 2700 MHz, VSWR 2, Gain 5 dBi4900 MHz ... 6425 MHz, VSWR 2.1, Gain 8 dBiGPS: 1574.4 MHz ... 1576.44 MHz, VSWR 1.5 |
Flammability rating | EN 45545-2 |
Antenna family | SENCITY® Rail Low Profile |
Back plate/base plate plating | Passivated (Plating) |
Storage temperature | -55 °C ... 85 °C |
Operation temperature | -40 °C ... 85 °C |
Back plate/base plate colour | Grey |
Product code | 1399.99.0032 |
Weight | 0.527 kg |