Skip to main content
Til toppen

SPUMA 400-FR

Produktnummer: 84040210
Huber Suhner
Lagerbeholdning:

Installation Temperature max. 60°C
Operating Temperature min. -40°C
Attenuation Coefficient b max. 0.0088
Attenuation Coefficient b 0.008
Attenuation Coefficient a 0.1241
Attenuation Coefficient a max. 0.1365
Calculated Power true
Centre Conductor Diameter 2.74mm
Centre Conductor Material Aluminium / Copper
Inner Cond Res DC 4.75Ohm/km
Installation Temperature min. -20°C
Operating Temperature max. 85°C
Outer Conductor 2 Description Outer conductor
Outer Conductor 3 Description Outer conductor
Outer Conductor 4 Description Outer conductor
Screen Frequency max. 6GHz
Outer Cond Resistance DC 6.06Ohm/km
Outer Cond1 Coverage 100%
Outer Conductor1 Diameter 7.4mm
Outer Conductor1 Material Aluminum / PES
Outer Cond2 Coverage 78%
Outer Conductor2 Diameter 8.15mm
Outer Conductor2 Material Copper, Tin plated
2002/96/EC (WEEE) no special marking needed
Class 1148
2006/1907/EC (REACH) compliant
2000/53/EC (ELV) compliant
Armoring 1 Description Armor
Armoring 2 Description Armor
Armoring 3 Description Armor
Armoring 4 Description Armor
Cable Category Flexible RF cable
Cable Family Spuma: Flexible, low-loss RF cables (LMR* alternatives)
Kabelgruppe - Kabel U30
Calc IL/Power up to Freq 17MHz
Capacitance 78pF/m
Centre Conductor Design Wire
Cold Bend Test MIL-C-17 § 4.8.19
CW Power 600W
CW Power Frequency 1GHz
Description 50 Ohm, 6 GHz, 85°C, ø10.25 mm, LSFH jacket, Flame retardant, UL AWM style 1354
Dielectric Diameter 7.24mm
Dielectric Material SPE (Foamed Polyethylene)
Distribution txt LMR* alternative, 50 Ohm, 6 GHz, 85°C, ø10.25 mm, LSFH jacket, Flame retardant, UL AWM style 1354
Fire Test a UL 1581 § 1100
Fire Test b UL 1581 § 1090
Fire Test c IEC 60332-3-24
Fire Test d EN 60332-1-2
Halogen Free true
Halogen Test IEC 60754
ID SPUMA_400-FR
Impedance 50Ohm
Impedance Tolerance ± 2Ohm
Insulation Resistance 1000000MOhm/m
Jacket Colour RAL 9005 - bk
Jacket Diameter 10.25mm
Jacket Material LSFH (modified polyethylene)
Jacket Tolerance 0.1mm
2011/65/EC (RoHS) compliant
Number of Screens 2
Only as Assembly false
Operating Frequency 6GHz
Operating Voltage 1.6kV
Outer Conductor1 Design longitudinal Foil
Outer Conductor2 Design Braid
Print on Jacket HUBER+SUHNER SPUMA 400-FR 50 Ohm (UL logo) AWM Style 1354 (production order number)
Propagation Velocity 85% of c
Repeated Bend Radius 100mm
Weight 11.5kg/100m
Screen Effectiveness 90dB
Signal Delay 3.9ns/m
Smoke Test EN 61034-2
Specification Voltage 30kV
Static Bend Radius 25mm
Temperature Rating UL 60°C
Test Voltage 3kV
OBJECT_ID 7516322
Espen Johannessen
Business Area Manager Contract manufacturers and Wholesalers Vis telefon Vis e-post
SPUMA 400-FR-01

Produktnummer: 84132035
Lagerbeholdning:
CNT-400-fr-500m

Produktnummer: CNT-400-FR-500M
Lagerbeholdning:
Fra:
Lenker
Language
Min side