Skip to main content
Til toppen

SPUMA 240-FR-01

Produktnummer: 85021563
Huber Suhner
Lagerbeholdning:

Installation Temperature max. 60°C
Operating Temperature min. -40°C
Attenuation Coefficient b max. 0.0102
Epsilon r 1.47
Attenuation Coefficient b 0.009
Attenuation Coefficient a 0.257
Attenuation Coefficient a max. 0.2858
Calculated Power true
Centre Conductor Diameter 1.42mm
Centre Conductor Material Copper
Inner Cond Res DC 10.89Ohm/km
Installation Temperature min. -20°C
Operating Temperature max. 85°C
Outer Conductor 2 Description Outer conductor
Outer Conductor 3 Description Outer conductor
Outer Conductor 4 Description Outer conductor
Screen Frequency max. 6GHz
Outer Cond Resistance DC 9.35Ohm/km
Outer Cond1 Coverage 100%
Outer Conductor1 Diameter 3.94mm
Outer Conductor1 Material Aluminum / PES
Outer Cond2 Coverage 94%
Outer Conductor2 Diameter 4.52mm
Outer Conductor2 Material Copper, Tin plated
2002/96/EC (WEEE) no special marking needed
Class 1148
2006/1907/EC (REACH) compliant
2000/53/EC (ELV) compliant
Alternative Cable SPUMA_240
Armoring 1 Description Armor
Armoring 2 Description Armor
Armoring 3 Description Armor
Armoring 4 Description Armor
Cable Category Flexible RF cable
Cable Family Spuma: Flexible, low-loss RF cables (LMR* alternatives)
Kabelgruppe - Kabel X28
Calc IL/Power up to Freq 17MHz
Capacitance 78.9pF/m
Centre Conductor Design Wire
Cold Bend Test MIL-C-17 § 4.8.19
CW Power 260W
CW Power Frequency 1GHz
Description 50 Ohm, 6 GHz, 85°C, ø6.17 mm, LSFH jacket, Flame retardant, Railway and CPR qualified
Dielectric Diameter 3.82mm
Dielectric Material SPE (Foamed Polyethylene)
Distribution txt LMR* alternative, 50 Ohm, 6 GHz, 85°C, ø6.17 mm, LSFH jacket, Flame retardant, Railway and CPR qualified
Fire Test a IEC 60332-1
Fire Test b IEC 60332-3-25
Halogen Free true
Halogen Test IEC 60754
ID SPUMA_240-FR-01
Impedance 50Ohm
Impedance Tolerance ± 2Ohm
Insulation Resistance 1000000MOhm/m
Jacket Colour RAL 9005 - bk
Jacket Diameter 6.17mm
Jacket Material LSFH (modified polyethylene)
Jacket Tolerance 0.1mm
2011/65/EC (RoHS) compliant
Number of Screens 2
Only as Assembly false
Operating Frequency 6GHz
Operating Voltage 0.9kV
Outer Conductor1 Design longitudinal Foil
Outer Conductor2 Design Braid
Print on Jacket HUBER+SUHNER SPUMA 240-FR-01 50 Ohm Cca-s1,d0,a1 (production order number)
Propagation Velocity 82.6% of c
Repeated Bend Radius 53mm
Weight 6.1kg/100m
Screen Effectiveness 90dB
Signal Delay 4.05ns/m
Smoke Test EN 61034-2
Static Bend Radius 14mm
Test Voltage 1.5kV
UV Resistance Test ISO 4892-2A
OBJECT_ID 8711483
Espen Johannessen
Business Area Manager Contract manufacturers and Wholesalers Vis telefon Vis e-post
Lenker
Language
Min side